MIX series I/O -                Modbus/RS485     Modbus/TCP      BACnet/MSTP    BACnet/IP

The product group of I/O modules of the MIX series has been designed for building distributed control systems using JACE or AAC20 devices. In order to ensure high versatility and price performance, all the MIX Series modules have been equipped with the most commonly used types of I/O in building automation (MIX of all types of I/O in one unit). In order to meet the tight market requirements, the modules are factory-equipped with the two most popular open communication protocols: Modbus (ASCII, RTU, TCP/IP) and BACnet (MSTP, IP), which are selected using DIP switches. There are two versions of the modules, namely: modules with interface RS485, and modules with interfaces 2x Ethernet and RS485. Devices with interfaces 2x Ethernet and RS485 have the added functionality of " Modbus Gateway TCP/IP to Modbus ASCII/RTU", enabling you to connect additional modules / devices that communicate via Modbus RS485.

MIX18

MIX18 I/O module has got on board 1x RS485 interface and 5DI – Digital Input: dry contact, fast pulse counter up to 100Hz with EEPROM memory. 5UI – Universal Input: volt input 0-10VDC, fast pulse counter up to 100Hz with EEPROM memory, resistive input 0-1000kΩ, 4AO – 0-10 VDC max. load 20mA, 4DO – Digital Outputs relay 230V AC, 3A max. The module is factory-equipped with the two most popular open communication protocols: Modbus (ASCII, RTU) and BACnet (MSTP), which are selected using DIP switches.

MIX18-IP

MIX18-IP I/O module has got on board 2xEthernet interface, 1x RS485 interface and 5DI – Digital Input: dry contact, fast pulse counter up to 100Hz with EEPROM memory. 5UI – Universal Input: volt input 0-10VDC, fast pulse counter up to 100Hz with EEPROM memory, resistive input 0-1000kΩ, 4AO – 0-10 VDC max. load 20mA, 4DO – Digital Outputs relay 230V AC, 3A max. The module is factory-equipped with the two most popular open communication protocols: Modbus TCP/IP with built in Modbus Gateway to RS485 and BACnet IP, which are selected using DIP switches.

MIX38

MIX38 I/O module has got on board 1x RS485 interface and 12DI – Digital Input: dry contact, fast pulse counter up to 100Hz with EEPROM memory. 8UI – Universal Input: volt input 0-10VDC, fast pulse counter up to 100Hz with EEPROM memory, resistive input 0-1000kΩ, 6AO – 0-10 VDC max. load 20mA, 12DO - Digital Outputs relay 230V AC, 3A max. The module is factory-equipped with the two most popular open communication protocols: Modbus (ASCII, RTU) and BACnet (MSTP), which are selected using DIP switches.

MIX38-IP

MIX38-IP I/O module has got on board 2xEthernet interface, 1x RS485 interface and 12DI – Digital Input: dry contact, fast pulse counter up to 100Hz with EEPROM memory. 8UI –Universal Input: volt input 0-10VDC, fast pulse counter up to 100Hz with EEPROM memory, resistive input 0-1000kΩ, 6AO – 0-10 VDC max. load 20mA, 12DO - Digital Outputs relay 230V AC, 3A max. The module is factory-equipped with the two most popular open communication protocols: Modbus TCP/IP with built in Modbus Gateway to RS485 and BACnet IP, which are selected using DIP switches.